Search Download Contact

Nozzles         Spring cap nozzles         Mixer nozzles         Filter nozzles         Reverse current cut-off         Adaptor         Heating technology         Spraying units         Heat insulation plates           more products

Mixer filter to protect the hot runner system

 

The mixer filter protects the hot runner system from blockages an damages. Foreign bodies of any kind and only partially melted granulate with a particle size down to 1 mm are retained. This ensures problem-free, economic production especially when using regenerated materials.

The mixer filters (protector) are the same size as our mixer nozzle and can be placed at any point because they are not dependent on the direction of flow. In complete orders the nozzle casing will be adjusted to the lenght of the mixer filter. When mixer nozzle units are already in place, 2 static mixer elements can be exchanged for the mixer filter.

Main dimensions of the mixer filter
Typ
I.D.
in mm
O.D.
in mm
NSP
BSP/TSP = 1 mm
LF
in mm
LME
pieces
MF 12-18
12
18
6
16
2
MF 18-26
18
26
8
22,5
2
MF 22-30
22
30
11
27
2
MF 27-35
27
35
13
33
2
MF 33-42
33
42
15
40
2
MF 40-50
40
50
19
48
2


LF Length of the filter
LME Length of the mixer elements
I.D. Inner diameter
O.D. Outer diameter
BSP Disc filter width
TSP Disc filter depth